[Mirrors]

Notes on the Troubleshooting and Repair of Computer and Video Monitors

Contents:


  10.4) Low or no high voltage


Most of these problems are due to faults in the horizontal deflection
system - shorted HOT, shorted windings or HV rectifiers in the flyback,
defective tripler, or other bad parts on the primary side of the flyback.

In addition, with auto-scan monitors, the incorrect voltage or other
component could be selected due to a logic fault or a problem with the
selection relay or other circuitry.

However, if you discover an inch layer of filth inside the monitor, the HV
could simply be shorting out - clean it first.

In most cases, these sorts of faults will put an excessive load on the
horizontal output circuits so there may be excessive heating of the HOT
or other components.  You may hear an audible arcing or sizzling sound from
internal shorts in the flyback or tripler.  Either of these may bet hot,
crack, bulge, or exhibit visible damage if left on with the fault present.

Many modern monitors do not regulate HV directly but rather set it via
control of the low voltage power supply to the HOT (B+), by snubber
capacitors across the HOT, and the turns ratio of the flyback.  The
HV is directly related to the B+ so if this is low, the HV will be low
as well.  Faulty snubber capacitors will generally do the opposite - increase
the HV and the X-ray protection circuits may kick in.  However, low HV
is also a possibility.  The only way the turns ratio of the flyback can
change is from a short which will manifest its presence in other ways as
well - excessive heating and load on the horizontal output circuits.

While a shorted second anode connection to the CRT is theoretically
possible, this is quite unlikely (except, as noted, due to dirt).


  10.5) Excessive high voltage


Any significant increase in HV should cause the X-ray protection circuits
to kick in and either shut down the set or modify the deflection in such
a way as to render it harmless.

Symptoms include arcing/sparking of HV, smaller than normal picture, and
under certain scenarios, possible excessive brightness.

Causes of the HV being too high are:

1. Excess B+ voltage to the HOT.  The likely cause is to a low voltage
   regulator failure.

2. Open snubber capacitors across the HOT.  These are under a lot of
   stress and are located near hot components so failure is possible.

3. Incorrect excessively long scan drive to HOT caused by failure of
   horizontal oscillator/sync circuits.  However, other things like the
   HOT will probably blow up first.  The picture will definitely be
   messed up.  This is more likely with auto-scan monitors than TVs
   since what is too long for one scan range may be correct for another
   and the selection circuitry is confused or broken.

4. Failure of HV regulator.  Actual HV regulators are uncommon today but
   the HV may controlled by a feedback voltage from a divider (focus or
   screen, or its own) or a secondary winding on the flyback setting the
   B+ or drive timing.  This may result in an underscanned (smaller than
   normal) picture if only the HV and not the deflection voltages as well
   are derived from the same supply.

In one example of (4), a arcing of the HV in a Conrac studio monitor resulted
in the destruction of the HV switchmode inverter transistor (this used
a separate HV supply) and a fusable resistor.  The cause was an open HV
feedback resistor divider allowing the HV to increase drastically.


  10.6) Snaps, crackles, and other HV breakdown


Various problems can result in occasional or sustained sparking or arcing
sounds from inside the monitor.  Note that a static electricity buildup
is common on the front of the screen.  It is harmless and there iss nothing
you can do about it anyhow.

The following may result in occasional or sustained sounds not commonly
associated with a properly working TV or monitor.  There may or may not be
flashes or blanking of the screen at the same time as the audible noise.
See the same-named sections that follow for details.

* Arcing, sparking, or corona from CRT HV anode (red wire/suction cup).

* Arcing at CRT sparkgaps.

* Arcing from flyback or vicinity.

* Arcing due to bad connections to or disconnected CRT return.

* Flashovers inside the CRT.


  10.7) Arcing, sparking, or corona from CRT HV anode (red wire/suction cup)


Symptoms could include a sizzling corona or more likely, an occasional
or rapid series of sharp snaps - possibly quite loud and quite visible - from
the anode cap on the CRT to the grounded coating on the outside of the CRT or
a chassis ground point (or any other conductor nearby).  Corona is a high
resistance leakage through the air without total breakdown.  The snapping
is caused by the sudden and nearly complete discharge of the CRT anode
capacitance through a low resistance ionized path similar to lightning.

There are two likely causes:

1. Dirt, dust, grime, around and under the suction cup on the CRT are
   providing a discharge path.  This may be more severe in humid weather.
   Safely discharge the HV and then remove and thoroughly clean the HV
   suction cup and the area under it and on the CRT for several inches
   around the HV connection.  Make sure there are no loose wires or other
   possible places for the HV to discharge to in the vicinity.

2. The high voltage has gone through the roof.  Usually, the X-ray protection
   circuitry should kick in but it can fail.  If cleaning does not help,
   this is a likely possibility.  See the sections: "High voltage shutdown due to X-ray protection circuits" and "Excessive high voltage".


  10.8) Arcing at spark gaps and gas discharge tubes on CRT neck board or elsewhere


These are protective devices intended to breakdown and divert excessive voltage
away from the CRT (usually).

This is rarely due to a defective sparkgap or gas discharge tube but rather is
a safety mechanism like a fuse designed to protect the internal electrodes of
the CRT if the focus or screen voltage should become excessive.  The sparkgap
breaks down first and prevents internal arcing in the CRT.  These sparkgaps
may be built into the CRT socket as well.

Arcing at a sparkgap or a glowing or flashing discharge tube may be accompanied
by total loss of picture or bad focus, brightness or focus fluctuations, or
any of a number of similar symptoms.  A common cause is a breakdown inside the
focus divider (usually part of the flyback or tripler) but could also be due to
excessive uncontrolled high voltage due to a failure of the B+ regulator or HOT
snubber capacitor, or (ironically) even a short inside the CRT.

* Spark gaps may be actual two or three pin devices with seemingly no insides,
  part of the CRT socket, or printed on the circuit board itself.

* Gas discharge tubes look like small neon lamps (e.g., NE2) but could be
  filled with some other gas mixture to provide a controlled higher breakdown
  voltage.

Therefore, like a fuse, don't just replace or disable these devices, locate and
correct underlying problem.  The CRT makes an expensive fuse!


  10.9) Arcing from flyback or vicinity


Arcing may be visible or audible and result in readily detectable levels
of ozone.  Note that very slight traces of ozone may not indicate anything
significant but if the TV smells like an office copier, there is probably
some discharge taking place.

WARNING: It is possible for arcing to develop as a result of excessive high
voltage.  Symptoms might be a smaller than normal excessively bright picture
but this may not be able to be confirmed until the flyback is repaired or
replaced.  See the section: "Excessive high voltage".

* On the HV output, it will probably be a loud snapping sound (due to the
  capacitance of the CRT) with associated blue/white sparks up to an inch or
  more in length.  If the arc length is short enough, this may turn into a
  nearly continuous sizzling sound with yellow/orange arc and melting/burning
  plastic.

* Prior to the HV rectifier, it will likely be a continuous sizzle with
  orange/yellow/white arc and melting/burning plastic or circuit board
  material.

* Internal arcing in the flyback may be audible and eventually result in
  a bulging and/or cracked case (if some other component doesn't fail first
  as this would take some time to develop).

* A corona discharge without actual sparks or a visible well defined arc
  is also possible.  This may be visible in a totally dark room, possibly
  more likely when the humidity is high.  A thorough cleaning to remove all
  dust and grime may be all that is needed in this case.

* If the arc is coming from a specific point on the flyback - a crack or
  pinhole - this may be patched well enough to confirm that the rest of the
  monitor is operational and a new flyback is worth the money.  Otherwise,
  there is no way of knowing if the arcing may have damaged other circuitry
  until a replacement flyback - possibly money wasted - arrives.

  To attempt a repair, scrape off any dirt or carbon that is present along the
  path of the arcing and its vicinity.  Then, clean the area thoroughly with
  alcohol and dry completely.  Otherwise, the dirt and carbon will just act as
  a good conductor and the arcing will continue under your repair!  Several
  layers of plastic electrical tape may be adequate for testing.  Multiple
  coats of high voltage sealer or non-corroding RTV silicone (if it smells like
  viniger - acetic acid - as it cures, this may get in and affect the windings)
  would be better if the objective is an actual repair.  This may prove to be
  a permanent fix although starting the search for a source for a new flyback
  would not hurt just in case.  The arc most likely did damage the insulation
  internally which may or may not be a problem in the future.

  Also see the section: "Dave's complete procedure for repair of an arcing flyback".

* In some cases, the pinhole or crack is an indication of a more serious
  problem - overheating due to shorted windings in the flyback or excessive
  secondary load.

* If the arc is from one of the sparkgaps around the CRT or the CRT socket,
  this could also be a flyback problem indicating internal shorts in the
  focus/screen network.

* If the arcing is inside the CRT, this could indicate a bad CRT or a problem
  with the flyback focus/screen network and no or inadequate sparkgap
  protection.

Where repair seems possible, first, clean the areas around the arc thoroughly
and then try several layers of plastic electrical tape.  If the TV works
normally for say, an hour, then there is probably nothing else wrong and you
can try for a proper sealing job or hope that tape holds out (put a few more
layers on - each is good for about 8-10 KV theoretically).

Once I had a TV where the main problem was a cracked flyback arcing
but this took out one of the fusable resistors for the power supply to
the *vertical* output so the symptoms included a single horizontal line.
Don't ask me to explain - replacing that resistor and the flyback (the
flyback tested good, but this was for someone else) fixed the TV.

In another case, a pinhole developed in the flyback casing probably
due to poor plastic molding at the time of manufacture.  This resulted in
a most spectacular case of sparking to a nearby bracket.  A few layers of
electrical tape was all that was needed to affect a permanent repair.

However, replacement is really the best long term solution both for reliability
as well as fire risk.

(From: Bert Christensen (rosewood@interlog.com)).

It may well last a long time. The insulation breakdown was probably in the
area of the rectifier section rather than the flyback section. I have repaired
several units in the same way but I have generally replaced the flyback before
sending back to the customer. I am worried that the repair will not hold and
that a fire could start. I have no desire whatsoever to be sued by some fire
insurance company.

I am always reminded by the experience that Zenith had with its System 3
chassis a few years ago. They burned and caused many house fires including
one in the governor's mansion in Texas. Zenith spent mega bucks on that one.
They also spent mega-bucks on their 'safety capacitor' mess a few years
before that.


  10.10) Dave's complete procedure for repair of an arcing flyback


(From: Dave Moore (penguin@datastar.net).

First I clean the afflicted area with Electromotive spray from Autozone. It's
for cleaning alternators.  On Z-line I remove the focus control and wash with
the alternator cleaner and a tooth brush until all dirt and carbon deposits
are removed. Then I take an xacto knife and carve out the carbonized hole
where the arcing broke through. Then take your soldering iron and close the
hole by melting adjacent plastic into it. (clean any solder off your iron with
solder-wick first). Then cut some plastic off of some other part off the
flyback where it wont be needed and use this to plastic weld (with your iron)
a hump of a patch into and over the arc hole. Smooth and seal with iron. Next
apply as thick a layer of silicone rubber as you can and let dry overnight.


  10.11) Spark gaps and gas discharge bulbs on CRT neck board or elsewhere


These are protective devices intended to breakdown and divert excessive voltage
away from the CRT (usually).

* Spark gaps may be actual two or three pin devices with seemingly no insides
  or printed on the circuit board itself.

* Gas discharge bulbs look like small neon lamps (e.g., NE2) but could be
  filled with some other gas mixture to provide a controlled higher breakdown
  voltage.

Arcing at a spark gap or a flashing or glowing gas discharge tube may indicate
excessive high voltage, a short in the focus/screen divider network of the
flyback, a short in the CRT, or some other fault resulting in abnormally high
voltage on its terminals.


  10.12) Arcing due to bad connections to or disconnected CRT return


The Aquadag coating on the outside of the CRT is the negative plate of the HV
filter capacitor.  If this is not solidly connected to the HV return, you will
have your 25 KV+ trying to go where it should not be.  There should be a wire
solidly attached to the CRT neck board or chassis.  Without this, voltage will
build up until it is able to take some other path - possibly resulting in
damage to sensitive solid state components in the process.  Therefore, is is
important to rectify the situation.

Warning: If you find this disconnected, don't just attach it anywhere.  You
may instantly kill ICs or other solid state components.  It must be connected
to the proper return point on the CRT neck board or chassis.


  10.13) Flashovers inside the CRT


Due to sharp edges on the electron gun electrodes, impurities, and other
manufacturing defects, there can be occasional arcing internal to the
CRT.  Properly designed HV, deflection, and power supply circuits can
deal with these without failing but not all monitors are designed well.

There is nothing you can do about flashovers assuming your HV is not
excessive (see the section: "Excessive high voltage".  If these persist
and/or become more frequent, a new CRT or new monitor will be needed.


  10.14) Ozone smell and/or smoke from monitor


Smoking is just as bad for monitors as for people and usually more quickly
terminal (no pun....).

White acrid smoke may indicate a failed electrolytic capacitor in the
power supply probably in conjunction with a shorted rectifier.  Needless to
say, pull the plug at once.

A visual inspection should be able to easily confirm the bad capacitor as it
will probably be bulging and have condensed residue nearby.  Check the
rectifier diodes or bridge rectifier with an ohmmeter.  Resistance across
any pair of leads should be more than a few ohms in at least one direction.
Remove from the circuit to confirm.  Both the faulty diode(s) and capacitor
should be replaced (though the capacitor may work well enough to test
with new diode(s).

If a visual inspection fails to identify the smoking part, you can probably
plug the monitor in for a few seconds until the source of the smoke is obvious
but be prepared to pull the plug in a real hurry.

If the smell/smoke is coming from the flyback, then it has probably gone
belly up.  You may be able to see a crack or bulge in the case.  While
the flyback will definitely need to be replaced, it is likely that nothing
else is wrong.  However, it might be prudent to use a Variac when performing
initial testing with the replacement just in case there is a secondary
short circuit or excess HV problem.


  10.15) X-ray and other EM emission from my monitor?


X-ray radiation is produced when a high velocity electron beam strikes
a target containing heavy metals.  In a modern monitor, this can only
take place at the shadow mask/aperture grille and phosphor screen of the CRT.

For X-rays, the amount of radiation (if any) will be proportional to
brightness.  The energy (determined by the CRT high voltage, called KVP
in the medical imaging field) is not affected.  This is one reason many
monitors and TVs are designed with brightness limiting circuits.

In any case, there will be virtually no X-ray emissions from the front of
the CRT as the glass is greater than an inch thick and probably contains
some lead for added shielding.  Also see the section: "Should I be worried about X-ray exposure while servicing a TV or monitor?".

Electromagnetic radiation (EM) is produced mostly from the deflection yoke
and to a lesser extent from some of the other magnetic components like
transformers and inductors.  Depending on monitor design (some are
specifically designed to reduce this), EM emissions can vary quite a bit.
Frequencies range from the 50/60 Hz of the power line or vertical scan rate
to several hundred KHz in the AM broadcast band.  The intensity and spectral
distribution will vary depending on horizontal and vertical scan rate.

A totally black screen will reduce X-ray emission to zero.  It will not
affect EM emissions significantly as most of this comes from the magnetic
parts, particularly the deflection yoke.

There is no measurable microwave, IR, or UV radiation.

I refuse to get into the discussion of what, if any, health problems result
from low level EM emissions.  There is simply not enough data.


  10.16) Should I be worried about X-ray exposure while servicing a TV or monitor?


The only source of X-rays in a modern TV or monitor is from the CRT.  X-rays
are generated when a high velocity electron beam strikes a heavy metal target.
For anything you are likely to encounter, this can only happen in a vacuum -
thus inside the CRT.  The higher the voltage, the greater the velocity and
potential danger.  Really old TVs (prior to around 1975) may still have HV
rectifier and regulator tubes - other sources of X-rays.  However, modern TVs
and monitors implement these functions with solid state components.

The thick front CRT faceplate protects users adequately but there may be some
emission from the thinner sides.  At 25-30 KV (quite low as X-ray energies go)
X-rays will be stopped by almost any metal so what you have to worry about
is where there are no shields.  In addition, the CRT glass usually contains
some lead compounds to block X-ray emissions.

However, realistically, there is very little danger.  I would not worry about
exposure unless you plan to be sitting for hours on the sides, behind, or
under the TV or monitor - with a picture (there will be none if the screen is
black).

It is interesting that even those 1.5" Watchman and .5" camcorder viewfinder
CRTs have X-ray warning labels even though the high voltage used with these
isn't anywhere near high enough to be of any concern!


  10.17) Flyback got wet


You put your can of Coke where????

Who says these FAQs cannot be funny?

Needless to say, unplug the monitor immediately.  Inspect around the target
area for obviously blown or damaged components.  Test fuses and fusable
resistors.  Remove all traces of liquid - especially sugary or corrosive
liquid.  Use water first and then alcohol to promote drying.
Repair burnt solder connections and circuit board traces.
Once the monitor is entirely dried out, power it up - preferably through a
series light bulb and/or Variac until you are sure nothing else will
let loose.  Look, listen, and smell for any unusual behavior.  If it
now works, then consider yourself lucky.  If not, there may be damage
to transistors, ICs, or other components.

Another cause of this is using spray cleaner or a too wet rag on the front
of the CRT (other parts of the monitor, for that matter).  Any liquid
which drips inside (all too likely) may short out circuitry on the mainboard
with very expensive consequences.


  10.18) Blooming or breathing problems


There are several symptoms that are basically similar:

* Blooming is defined as an expansion of the raster or horizontal sections of
  the raster with bright material.  For example, switching between dark and
  light picture causes the size of the picture to expand by 10%.  A slight
  change in size is unavoidable but if it is greater than 1 or 2 percent from
  a totally black image to a full white one, this is either an indication of a
  defective monitor or one that is badly designed.  The cause is poor low or
  high voltage regulation.

  Check the B+ to the horizontal deflection.  This is usually well regulated.
  If it is varying in sympathy to the size changes, trace back to determine
  why the low voltage regulator is not doing its job.  The reason for the size
  change is that the high voltage is dropping and reducing the stiffness of
  the electron beam.

* Expansion of the raster width in areas of bright imagery is an indication 
  of short term regulation problems.  The video drive may be interacting
  with the other power supplies.  Check for ripple - this would be
  at the vertical scan rate - in the various regulated power supplies.
  The cause may be a dried up electrolytic capacitor - once you locate the
  offending voltage, test or substitute capacitors in that supply.

In both these cases, if this just started after some work was done to the
monitor, the brightness limiter and/or video drive may simply be set so
high that the monitor cannot supply enough current to the high voltage.
If the brightness is acceptable with these turned down slightly and still
have acceptable brightness, then there may be nothing wrong.

* Breathing is defined as a periodic change in the size of the raster which
  may be independent of what is displayed or its severity or frequency may
  be related to the brightness or darkness of the image.  This is another type
  of regulation problem and may be caused by bad electrolytic capacitors or
  other components in the low voltage power supplies.

  If the monitor uses a switchmode power supply or low voltage regulator
  separate from the horizontal deflection, first check its output(s) for a
  variation in voltage at the breathing rate.  Test with a light bulb or
  resistor load to confirm that the problem is here and not the deflection
  or remainder of the monitor.

* A condition with somewhat similar symptoms is bad focus - fuzzy picture - but
  only with bright (high beam current) scenes.  This could be just a matter of
  adjusting the focus control but may also indicate sub-optimal filament
  voltage due to bad connections or components in the filament circuit, or a
  tired worn CRT.  You won't get high beam current without some serious spot
  blooming (a fat beam because too much cathode area is used) and you will get
  cathode 'poisoning' after prolonged use.

  Visually inspect the neck of the CRT for the normal orange glow of the
  filaments and check for bad connections and bad parts.


  10.19) Erratic focus or screen (G2) voltage and/or controls on flyback


Symptoms may include fluctuating focus or brightness.  In extreme cases,
the result may be a too bright or dark picture or other behavior caused
by breakdown in the Focus/Screen(G2) divider network.

Usually, this will require flyback replacement to repair reliably.  Sometimes,
the section with the controls can be snapped apart and cleaned but this is not
common.

First, just try rotating the screen (G2) control back and forth a few times.
This may clean up the contacts and eliminate the erratic behavior.  Possibly,
positioning it a bit to one side of the original location will help.  Then,
use the individual or other master background/bias adjustments to compensate
for the improper brightness.

If this doesn't help, here is a 'well it's going in the dumpster anyhow'
procedure to try:

After discharging the CRT (so you don't get zapped) drill a tiny hole in
the plastic cover near the bad control.  Be careful you don't damage anything
inside - you just want access to the contacts of the controls.  Use a hand
drill with, say, a 1/16" bit.  Don't drill more than about 1/8" deep which
should enter the airspace.  Then spray some contact cleaner through the
hole and work the controls.  Wait sufficient time for the everything to dry
COMPLETELY and see if behavior changes (or it works at all).

This is a 'you have got to be kidding' type of repair so no guarantees :-).

If by some miracle it does work, fill the hole with a drop of RTV or just
put a couple of layers of electrical tape over it.


  10.20) Focus/Screen divider bypass surgery


This is kludge number 41256 but may be the difference between a bit more life
and the dumpster.

If the previous extreme measures don't help, then it may be possible to simply
substitute a good divider network externally.

Note that if there is evidence of internal breakdown in the divider of the
original flyback (hissing, cracks, overheating, bulging case, etc.), this will
not work unless you can disconnect it from its HV connection.

There are two issues:

1. Is this a stable situation?  Even if you provide an external substitute,
   the parts inside the flyback may continue to deteriorate eventually
   resulting in other more total failure of the flyback or worse.

2. If you provide an external focus/screen divider, it must be done is such a
   manner (including proper mounting and super insulation) such that it cannot
   be called into question should there be a fire where the monitor is even
   the slightest bit suspect.

Various size external focus/screen divider networks can be purchased but
whether this is truly a cost effective solution is not obvious.

(From: Larry Sabo (sabo@storm.ca)).

I just ordered a 'bleeder resistor' from Data Display Ltd (Canadian sub of
CCS) to use as a cure for flybacks with flaky focus/screen pots. It contains
focus and screen pots, and costs Cdn$ 16.99, which is a lot less than a
complete flyback, that's for sure. I expect it will be compatible with quite a
wide range of flybacks.

I have used bleeder resistor assemblies from duff flybacks a couple of times
with good success. You connect the HV lead into the HV cap of the original
flyback, ground all pins of the sub flyback, and use the focus and screen
leads from the sub bleeder assembly in place of the originals.

Looks like hell but works fine. Mounting (and securing) the substitute is a
challenge given the limited space available. I only use this approach on what
would otherwise be uneconomical to repair, and always advise the owner or
customer of the cobbling job. It also enables you to verify whether it is
the flyback that needs replacement, versus the CRT.


  10.21) Decaying or erratic focus or screen (G2) voltages


The following applies to both CRT focus voltage (which should be a few KV)
and screen or G2 voltage (which should be several hundred V).

"The screen voltage will come up to normal after sitting over night, 400 V or
 so. After approximately 5 minutes or slightly longer, I hear a slight arcing.
 From that point on, the screen voltage will wander anywhere from 75 V up to
 maybe 150 V. Adjustment of the screen control on the flyback has only a small
 effect and is not permanent. Removing the CRT pcb results in the screen
 voltage returning to normal."

This is very likely a short between electrodes inside the CRT unless there
is something on the neck board that is breaking down as a result of some
connection to the CRT.  The flyback should largely not know the difference
with the socket plugged into the CRT.

One possibility is that glue used to hold components down on some circuit
boards has deteriorated and turned conductive.  Check for tan to brown
stuff shorting traces on the CRT neck board.  If this is present on the
focus or screen traces or wires, it may just be your problem.  Scrape off
all of the old glue and then clean thoroughly.  Repair any damaged traces.

What happens to the HV?  A HV breakdown possibly inside the CRT would result
in all the voltages being dragged down.

What happens to the picture?

If you connect a charged HV capacitor (guessing a couple hundred volts,
a couple microfarads) between G2 and G1 or focus, you **will** know if
tapping the neck results in a momentary short!  I cannot predict whether
this will be a temporary cure or permanent killer.  See the section:
"Rescuing a shorted CRT".

Here is another thing to try: put a 100 M ohm or so resistor between SCREEN
and the CRT socket.  This should not affect the behavior much until the
failure occurs.  Then, check the voltage on both sides with a high impedance
voltmeter (1000 M).  If the CRT is arcing, it will be much lower on the CRT 
side and will probably fluctuate.  You can play similar games with focus
voltage.


  10.22) Disconnecting focus wire from CRT driver board


In some cases, the focus wire - the not-so-fat wire from the flyback or focus
divider - may terminate directly in the CRT socket with no obvious means of
freeing it should flyback replacement be needed.

One alternative is simply to cut the wire in a location that is well away from
any place to short out, solder, and then do a  most excellent job of insulating
the splice.

However, you may find that the cap on the CRT socket snaps off using a thin
knife blade or screwdriver.  The wire may be soldered or just pressed in place
in such a way that pulling it out is difficult or impossible without removing
the cover.

(From: Raymond Carlsen (rrcc@u.washington.edu)).

The last one I worked on puzzled me for a few moments. See if you can see a
space between the little cup (where the wire enters the socket) and the socket
itself.  Pry up on the cap with a knife and it should pop right off. The wire
is soldered to a pin under it. Don't apply heat for very long... you may melt
the socket. 


  10.23) Focus or screen voltage drifts after warmup only when CRT is connected


"I have a 3-5 yr old monitor that loses screen voltage.  I believe that the
 problem is specific to the CRT or the flyback, either one is a guess I'd
 rather be sure of prior to ordering a part. 

 The screen voltage will come up to normal after sitting over night, 400 V or
 so. After approximately 5 minutes or slightly longer, I hear a slight arcing.
 From that point on, the screen voltage will wander anywhere from 75 V up to
 maybe 150 V.  Adjustment of the screen control on the flyback has only a
 small effect and is not permanent. Removing the CRT pcb results in the screen
 voltage returning to normal. 

 I cannot find the source of the arcing, as it happens quickly and I have
 always been on the other side of the set when it happens. I have replaced
 the crt socket, thinking the spark gap was arcing. I have checked the CRT
 for G1 and HK shorts on a sencore crt checker, it checks good, but I am aware
 that since it is an intermittent problem, that the checker probably will not
 catch it."

This sounds like a CRT short unless there is something on the neck board
that is breaking down.  The Sencore may not provide the same high voltages
as normal screen (several hundred volts) or focus (several thousand volts).
The flyback should largely not know the difference whether the screen or
focus electrode of the CRT is connected or not.  The current should be
negligible.

One possibility is that glue used to hold components down on some circuit
boards has deteriorated and turned conductive.  Check for tan to brown
stuff shorting traces on the CRT neck board.  If this is present on the
focus or screen traces or wires, it may just be your problem.  Scrape off
all of the old glue and then clean thoroughly.  Repair any damaged traces.

What happens to the HV?  A HV breakdown possibly inside the CRT would result
in all the voltages being dragged down.

What happens to the picture?

If you connect a charged HV capacitor (guessing a couple hundred volts,
a couple microfarads) between G2 and G1 or focus, you **will** know if
tapping the neck results in a momentary short!  I cannot predict whether
this will be a temporary cure or permanent killer.

Here is another thing to try: put a 100 M ohm or so resistor between SCREEN
(or FOCUS) and the CRT socket.  This should not affect the behavior much
until the failure occurs.  Then, check the voltage on both sides with a high
impedance voltmeter (>1000 M).  If the CRT is arcing, it will be much lower
on the CRT  side.

Go to [Next] segment
Go to [Previous] segment

Go to [Table 'O Contents]



Written by Samuel M. Goldwasser. | [mailto]. The most recent version is available on the WWW server http://www.repairfaq.org/ [Copyright] [Disclaimer]