IBM 127 / 230 (MO) Drive

obirwopt.exe OBI 127M R/W Optical Option Diskette 
127m_dos.exe OBI 127M R/W Optical Driver for DOS 
 

IBM 127MB Magneto-Optical (MO) Disk Drive

    If the Operating System is OS/2 and there are only FORMAT problems (read/write/copy is working), then Check the drivers installed for the MO-drive (CONFIG.SYS) If OPTICAL.SYS is used, then a replacement of OPTICAL.SYS can solve the problem 
    In all cases, you should first CLEAN the drive/media, before starting TESTs, or replacements. see Optical Disk Drive Parts for the appropriate tool for the drive in use. 

 Next find the DRIVE-TYPE you are working with (FAT / SMALL or 230MB) 
   1 .   FAT  On the FAT drive, on the upper left and right front side, you will find 3-sets of PIN's/jumper. 
   2.   SMALL  A sticker, describing all switch and jumper meaning, is on the Drive-bottom. 
   3.   230MB IBM 127MB Magneto-Optical (MO) Disk Drives. 

 FAT - Drive
 Left side Jumperblock 
      Leftmost Jumper -  MUST be PRESENT (default present) 
      Middle  Jumper -  Security jumper (default present) 
      Do not remove the security jumper unless you have a PS/2 computer with the security feature  and the privileged-access password is enabled. If the jumper is removed, and the PAP is not enabled, you will not be able to load or eject the  media. 
      Right Jumper -  MUST be OPEN  (no jumper) 

Right side Jumperblock (SCSI Address) 
      SCSI address Bit-4  -  Left Jumper 
      SCSI address Bit-2  -  Middle Jumper 
      SCSI address Bit-1  -  Rightmost Jumper 
 

 SMALL - Drive FUNCTION (DIP SWITCH ONLY SETUP) ( DIP S1 Switch)
 

FUNCTION
1
2
3
4
5
6
7
8
DEFAULT Setup (Factory) 
1
1
1
1
0
1
0
0
Create unit Attention
1
-
-
1
-
-
-
-
Disable Unit Attention 
0
-
-
1
-
-
-
-
Check SCSI Parity
-
1
-
1
-
-
-
-
Ignore SCSI Parity 
-
0
-
1
-
-
-
-
Device Type X'07' 
-
-
1
1
-
-
-
-
Device Type X'00' 
-
-
0
1
-
-
-
-
No Spin Up on POR 
-
-
-
-
1
-
-
-
Auto Spin Up on POR
-
-
-
-
0
-
-
-
No Security Mode (normal)
-
-
-
-
-
1
-
-
C2 Security Mode 
-
-
-
-
-
0
-
-
Without Power Saving Mode
-
-
-
-
-
-
1
-
With Power Saving Mode 
-
-
-
-
-
-
0
-
Reserved (MUST be OFF)
-
-
-
-
-
-
-
0
Mode Page 1,2,3,4 Support (With Device TYPE X'00') 
1
1
0
0
-
-
-
-

 

 FUNCTION (DIP SWITCH ONLY SETUP)  ( DIP S2 SWITCH - SCSI Address)
  +------------------------------------+
 |FUNCTION                    |1 2 3 4|
 |----------------------------+-------|
 |SCSI Addr. 0                |0 0 0 -|
 |----------------------------+-------|
 |SCSI Addr. 1                |1 0 0 -|
 |----------------------------+-------|
 |SCSI Addr. 2                |0 1 0 -|
 |----------------------------+-------|
 |SCSI Addr. 3                |1 1 0 -|
 |----------------------------+-------|
 |SCSI Addr. 4                |0 0 1 -|
 |----------------------------+-------|
 |SCSI Addr. 5                |1 0 1 -|
 |----------------------------+-------|
 |SCSI Addr. 6                |0 1 1 -|
 |----------------------------+-------|
 |SCSI Addr. 7                |1 1 1 -|
 |----------------------------+-------|
 |Disable SCSI Terminator     |- - - 1|
 |----------------------------+-------|
 |Enable SCSI Terminator      |- - - 0|
 +------------------------------------+

 FUNCTION (DIP SWITCH and CONNECTOR SETUP)

0 = DIP SW -Off
1 = DIP SW -ON
P =CONNECTOR Open
S = CONNECTOR Short to Ground  (CON C1-1)
H = HIGH (Output)
L = LOW  (Output)

  +----------------------------------------------------------------+
 |FUNCTION                    | CON C1    | DIP S1| DIP S2| CON C2|
 |----------------------------+-----------+-------+-------+-------|
 |Create Unit Attention       |- - - - - P|0 - 0 0|- - - -|S - S -|
 |----------------------------+-----------+-------+-------+-------|
 |Disable Unit Attention      |- - - - - P|0 - 0 0|- - - -|P - S -|
 |----------------------------+-----------+-------+-------+-------|
 |Device Type X'07'           |- - - - - P|0 - 0 0|- - - -|- S S -|
 |----------------------------+-----------+-------+-------+-------|
 |Device Type X'00'           |- - - - - P|0 - 0 0|- - - -|- S S -|
 |----------------------------+-----------+-------+-------+-------|
 |Mode Page 20 Support        |- - - - - S|1 1 1 -|- - - -|P P P -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 0              |- P P P - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 1              |- S P P - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 2              |- P S P - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 3              |- S S P - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 4              |- P P S - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 5              |- S P S - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 6              |- P S S - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |SCSI ADDRESS 7              |- S S S - -|- - - -|0 0 0 -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |Disable SCSI Terminator     |- - - - - -|- - - -|- - - 0|- - - S|
 |----------------------------+-----------+-------+-------+-------|
 |Enable SCSI Terminator      |- - - - - -|- - - -|- - - 0|- - - P|
 |----------------------------+-----------+-------+-------+-------|
 |----------------------------+-----------+-------+-------+-------|
 |Normal Mode       (Output)  |- - - - H -|- - - -|- - - -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |Power Saving Mode (Output)  |- - - - L -|- - - -|- - - -|- - - -|
 |----------------------------+-----------+-------+-------+-------|
 |----------------------------+-----------+-------+-------+-------|
 |Ground            (Output)  |L - - - - -|- - - -|- - - -|- - - -|
 +----------------------------------------------------------------+
 

 127MB MO-Drive DOS OS/2 CONFIG.SYS examples

CONFIG.SYS example  (FAT-drive used with DOS)
         DEVICE=C:\IBMRWOPT.SYS      /U

CONFIG.SYS example (SMALL-drive used withDOS)
     DEVICE=C:\OPTIMO\OPTIMO.EXE

      in an available OPTIMO.CFG file you will see
           rem  timeout 0
           adapter IBM # =0
           drive IBM3125 cid=2 lun =0

CONFIG.SYS example (FAT-drive used with OS/2)
         DEVICE=C:\OS2\SCSI.SYS /N :4
         DEVICE=C:\OS2\OPTICAL.SYS /N:4  /U

(some newer OPTICAL.SYS driver support /T:xx parameters (POWER-save option, after xx minutes.))
   NOTE: (OPTICAL.SYS parameter)
    /L   for LONG FORMAT
    /N:x Number of SCSI devices in the computer
    /Q   Quiet mode (no message during OS/2 startup)
    /U   Unattended mode (OS/2 assign the drive letter)

CONFIG.SYS example (SMALL-drive used with OS/2 V-2.0 or  higher)

  If you are running OS/2 V-2.1 or below, you MUST replace the existing FORMAT.COM file in the C:\OS2 directory, with the FORMAT.COM shipped with the OPTION. (Optical Disk Driver For OS/2 diskette)  (rename the original FORMAT.COM, do not delete !)

         BASEDEV = IBM2SCSI.ADD /LED  (only on PS/2 systems used)
         BASEDEV = OS2SCSI.DMD
         DEVICE=C:\OS2\MO.SYS /D1

°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°

IBM 230MB Magneto-Optical (MO) Disk Drives (Internal and External)

 Product Description The 230MB MO-drive meets the Small Computer System Interface-2 (SCSI-2) standards set by ANSI. This drive reads and writes both 128MB and 230MB optical media. The  SCSI supports data transfer rates up to 5 megabytes / sec.

System Type Settings
Thet following table indicates some possible combinations of the customization switch settings for several manufacturer computers.

.... for 230MB INTERNAL Drives
System Type       Position 1     Position 3
------------------------------------------
IBM PC               ON            ON
Apple Macintosh      OFF           ON
Sun                  OFF           OFF
DEC                  OFF           OFF

.... for 230MB EXTERNAL Drives
System Type      Position 3
----------------------------
IBM PC            ON
Apple Macintosh   ON
Sun               OFF
DEC               OFF

Termination SETUP (230MB - Internal Drive)

+---------------------------------------------------------------------+
|SCSI-ID              |INTERNAL |Apple / Sun  / DEC|      IBM PC      |
|                     | DIP-SW  | EXTERNAL - DRIVE | EXTERNAL - DRIVE |
|                     |4 3 2 1  |  Rotary Switch   |  Rotary Switch   |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 7         |- 1 1 1  |      7           |      F           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 6         |- 1 1 0  |      6           |      E           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 5         |- 1 0 1  |      5           |      D           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 4         |- 1 0 0  |      4           |      C           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 3         |- 0 1 1  |      3           |      B           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 2         |- 0 1 0  |      2           |      A           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 1         |- 0 0 1  |      1           |      9           |
|---------------------+---------+------------------+------------------|
|SCSI Addr. 0         |- 0 0 0  |      0           |      8           |
|---------------------+---------+------------------+------------------|
|Termination DISABLE  |1 - - -  |No Terminator     |No Terminator     |
|                     |         |conn.             |conn.             |
|---------------------+---------+------------------+------------------|
|Termination ENABLE   |0 - - -  |Terminator        |Terminator        |
|                     |         |connected         |connected         |
+---------------------------------------------------------------------+
 

Customization Switch Settings (230MB - Internal Drive)
      If you are not familiar with the customization switch, use the default settings (marked with (* )
      Write cache is used to improve performance of the Optical Drive by returning a write  complete status when the data to be written has been  loaded into the buffer memory of the Optical Drive. There is a small risk of the data being lost due to a  power loss or drive failure with write caching enabled.
      The user should choose either  performance improvement (write cache enabled) or fail-save data integrity (write cache      disabled)
     Position 4 defines how the Optical  Drive configures itself after it is turned on or using a SCSI Reset situation. This setting may be over-ridden by the write caching option chosen in the device driver. See the README.TXT files that come on the device driver diskettes for OS/2 and DOS for details.

+--------------------------------------------------------------------------------+
|SW-Pos|Setting|Description (INTERNAL drive)                                     |
|------+-------+-----------------------------------------------------------------|
| 1    |ON  (* |Enable unit attention on POR/SCSI reset                          |
|------+-------+-----------------------------------------------------------------|
| 1    |OFF    |With Position 3 ON:                                              |
|      |       |Disable Unit Attention on POR/SCSI reset (for Apple attachment)  |
|      |       |With Position 3 OFF:                                             |
|      |       |Mode Page 1,2,3,4 support (for DEC/SUN attachment)               |
|------+-------+-----------------------------------------------------------------|
| 2    |ON  (* |Check SCSI parity                                                |
|------+-------+-----------------------------------------------------------------|
| 2    |OFF    |Ignore SCSI parity                                               |
|------+-------+-----------------------------------------------------------------|
| 3    |ON  (* |Device type inquiry data is hex 07 (optical disk drive)          |
|------+-------+-----------------------------------------------------------------|
| 3    |OFF    |Device type inquiry data is hex 00 (hard disk drive)             |
|------+-------+-----------------------------------------------------------------|
| 4    |ON  (* |Write cache disabled after POR/SCSI reset                        |
|------+-------+-----------------------------------------------------------------|
| 4    |OFF    |Write cache enabled after POR/SCSI reset                         |
|      |       |(NOTE: with pos 1,2,3,4 set to ON,ON,OFF and OFF                 |
|      |       |respectively, write cache is disabled after Reset.)              |
|------+-------+-----------------------------------------------------------------|
| 5    |ON     |No spin-up on POR                                                |
|------+-------+-----------------------------------------------------------------|
| 5    |OFF (* |Spin-up automatically on POR                                     |
|------+-------+-----------------------------------------------------------------|
| 6    |ON  (* |Normal Mode                                                      |
|------+-------+-----------------------------------------------------------------|
| 6    |OFF    |C2 Security Mode                                                 |
|------+-------+-----------------------------------------------------------------|
| 7    |ON     |Default value of time interval hex FF (Do not enter power-down   |
|      |       |mode.)                                                           |
|------+-------+-----------------------------------------------------------------|
| 7    |OFF (* |Default value of time interval hex 05 (Enter power-down mode     |
|      |       |after 5 minutes.)                                                |
|------+-------+-----------------------------------------------------------------|
| 8    |OFF (* |Reserved (must remain OFF)                                       |
|------+-------+-----------------------------------------------------------------|
+--------------------------------------------------------------------------------+
 

Customization Switch Settings ( 230MB - External  Drive)
+--------------------------------------------------------------------------------+
|SW-Pos|Setting|Description (EXTERNAL drive)                                     |
|------+-------+-----------------------------------------------------------------|
| 1    |OFF (* |Must remain in the OFF position for the External Drive to        |
|      |       |function properly                                                |
|------+-------+-----------------------------------------------------------------|
| 2    |ON  (* |Check SCSI parity                                                |
|------+-------+-----------------------------------------------------------------|
| 2    |OFF    |Ignore SCSI parity                                               |
|------+-------+-----------------------------------------------------------------|
| 3    |ON  (* |Device type in inquiry data is hex 07 (optical disk drive)       |
|------+-------+-----------------------------------------------------------------|
| 3    |OFF    |Device type in inquiry data is hex 00 (hard disk drive)          |
|------+-------+-----------------------------------------------------------------|
| 4    |ON  (* |Write cache disabled after POR/SCSI reset                        |
|------+-------+-----------------------------------------------------------------|
| 4    |OFF    |Write cache enabled after POR/SCSI reset                         |
|      |       |(NOTE: with pos 1,2,3,4 set to ON,ON,OFF and OFF                 |
|      |       |respectively, write cache is disabled after Reset.)              |
|------+-------+-----------------------------------------------------------------|
| 5    |ON     |No spin-up on POR                                                |
|------+-------+-----------------------------------------------------------------|
| 5    |OFF (* |Spin-up automatically on POR                                     |
|------+-------+-----------------------------------------------------------------|
| 6    |ON  (* |Normal Mode                                                      |
|------+-------+-----------------------------------------------------------------|
| 6    |OFF    |C2 Security Mode                                                 |
|------+-------+-----------------------------------------------------------------|
| 7    |ON     |Default value of time interval hex FF (Do not enter power-down   |
|      |       |mode.)                                                           |
|------+-------+-----------------------------------------------------------------|
| 7    |OFF (* |Default value of time interval hex 05 (Enter power-down mode     |
|      |       |after 5 minutes.)                                                |
|------+-------+-----------------------------------------------------------------|
| 8    |OFF (* |Reserved (must remain OFF)                                       |
+--------------------------------------------------------------------------------+